Much more than just blast chillers! In addition to having the best cycle performance, they perform many other functions: defrosting, freezing, slow cooking. These features make them valuable all-rounders in the kitchen, supporting the creation of many different recipes. They are equipped with a touch screen with an intuitive and programmable interface. Discover the multiple functionalities of the Absolute range!
Models | Power supply | Sizes (W x D x H) | Files | More info | |
---|---|---|---|---|---|
MC051A-R290 MULTIF BLAST CHILLER 6 GN1/1 AIR | Elettrica | 790 x 820 x 900 | Download |
Detail
MC051A-R290 MULTIF BLAST CHILLER 6 GN1/1 AIR Multifunction blast chiller with air cooling system, tray capacity GN 1/1 x 10/6/5, distance between trays 35/53/70 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. High performance copper aluminium condenser class T, ambient temperature + 43°. Output per cycle (+65°/+10°) kg. 30. Output per cycle (+65°/-18°) kg. 20. Heating element in the door frame. Hot gas defrosting system. R452A ecological refrigerant fluid. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x430x400 mm. Minimum wheelbase for tray holder guides 17,5 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 50 mm. |
|
MC051AR-R290 MULTIF BLAST CHILLER 6 GN1/1 AIR MULTIF BLAST CHILLER 6 GN1/1 AIR NO TOP | Elettrica | 790 x 820 x 900 | Download |
Detail
MC051AR-R290 MULTIF BLAST CHILLER 6 GN1/1 AIR MULTIF BLAST CHILLER 6 GN1/1 AIR NO TOP Multifunction blast chiller with air cooling system, tray capacity GN 1/1 x 10/6/5, distance between trays 35/53/70 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. High performance copper aluminium condenser class T, ambient temperature + 43°. Output per cycle (+65°/+10°) kg. 30. Output per cycle (+65°/-18°) kg. 20. Heating element in the door frame. Hot gas defrosting system. R452A ecological refrigerant fluid. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x430x400 mm. Minimum wheelbase for tray holder guides 17,5 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 50 mm. Version without top for positioning under stand or worktop. |
|
MC051R MULTIF BLAST CHILLER 6 GN1/1 AIR P | Elettrica | 790 x 820 x 900 | Download |
Detail
MC051R MULTIF BLAST CHILLER 6 GN1/1 AIR P Multifunction blast chiller with remote air cooling system, tray capacity GN 1/1 x 10/6/5, distance between trays 35/53/70 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. Output per cycle (+65°/+10°) kg. 30. Output per cycle (+65°/-18°) kg. 20. Heating element in the door frame. Hot gas defrosting system. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x430x400 mm. Minimum wheelbase for tray holder guides 17,5 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 50 mm. Remote condensing unit not included. |
|
MC081A-R290 MULTIF BLAST CHILLER 8 GN 1/1 AIR | Elettrica | 790 x 870 x 1460 | Download |
Detail
MC081A-R290 MULTIF BLAST CHILLER 8 GN 1/1 AIR Multifunction blast chiller with air cooling system, tray capacity GN 1/1 x 18/12/9, distance between trays 36,5/55/73 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. High performance copper aluminium condenser class T, ambient temperature + 43°. Output per cycle (+65°/+10°) kg. 45. Output per cycle (+65°/-18°) kg. 30. Heating element in the door frame. Hot gas defrosting system. R452A ecological refrigerant fluid. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x450x730 mm. Minimum wheelbase for tray holder guides 18,25 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. |
|
MC081R MULTIF BLAST CHILLER 8 GN 1/1 AIR P | Elettrica | 790 x 870 x 1460 | Download |
Detail
MC081R MULTIF BLAST CHILLER 8 GN 1/1 AIR P Multifunction blast chiller with remote air cooling system, tray capacity GN 1/1 x 18/12/9, distance between trays 36/55/73 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. Output per cycle (+65°/+10°) kg. 45. Output per cycle (+65°/-18°) kg. 30. Heating element in the door frame. Hot gas defrosting system. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x450x730 mm. Minimum wheelbase for tray holder guides 17,5 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 60 mm. Remote condensing unit not included. |
|
MC121A-R290 MULTIF BLAST CHILLER 12 GN 1/1 AIR | Elettrica | 790 x 870 x 1810 | Download |
Detail
MC121A-R290 MULTIF BLAST CHILLER 12 GN 1/1 AIR Multifunction blast chiller with air cooling system, tray capacity GN 1/1 x 24/16/12, distance between trays 37/55/73 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. High performance copper aluminium condenser class T, ambient temperature + 43°. Output per cycle (+65°/+10°) kg. 65. Output per cycle (+65°/-18°) kg. 45. Heating element in the door frame. Hot gas defrosting system. R452A ecological refrigerant fluid. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x450x930 mm. Minimum wheelbase for tray holder guides 18,25 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. |
|
MC121R MULTIF BLAST CHILLER 12 GN 1/1 AIR P | Elettrica | 790 x 870 x 1810 | Download |
Detail
MC121R MULTIF BLAST CHILLER 12 GN 1/1 AIR P Multifunction blast chiller with remote air cooling system, tray capacity GN 1/1 x 24/16/12, distance between trays 37/55/73 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. Output per cycle (+65°/+10°) kg. 65. Output per cycle (+65°/-18°) kg. 45. Heating element in the door frame. Hot gas defrosting system. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x450x930 mm. Minimum wheelbase for tray holder guides 18,25 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 60 mm. Remote condensing unit not included. |
|
MC122A MULTIF BLAST CHILLER 24 GN 1/1 AIR | Elettrica | 1100 x 1080 x 1860 | Download |
Detail
MC122A MULTIF BLAST CHILLER 24 GN 1/1 AIR Multifunction blast chiller with air cooling system, tray capacity GN 1/1 x 44/28/22, distance between trays 38/57/75 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. High performance copper aluminium condenser class T, ambient temperature + 43°. Output per cycle (+65°/+10°) kg. 90. Output per cycle (+65°/-18°) kg. 60. Heating element in the door frame. Hot gas defrosting system. R452A ecological refrigerant fluid. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x930x880 mm. Minimum wheelbase for tray holder guides 18,75 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 60 mm. |
|
MC122R MULTIF BLAST CHILLER 24 GN 1/1 AIR P | Elettrica | 1100 x 1080 x 1860 | Download |
Detail
MC122R MULTIF BLAST CHILLER 24 GN 1/1 AIR P Multifunction blast chiller with remote air cooling system, tray capacity GN 1/1 x 24/16/12, distance between trays 37/55/73 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. Output per cycle (+65°/+10°) kg. 65. Output per cycle (+65°/-18°) kg. 45. Heating element in the door frame. Hot gas defrosting system. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x450x930 mm. Minimum wheelbase for tray holder guides 18,25 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 60 mm. Remote condensing unit not included. |
|
MC161A-R290 MULTIF BLAST CHILLER 16 GN 1/1 AIR | Elettrica | 790 x 870 x 1960 | Download |
Detail
MC161A-R290 MULTIF BLAST CHILLER 16 GN 1/1 AIR Multifunction blast chiller with air cooling system, tray capacity GN 1/1 x 28/18/14, distance between trays 37/55/73 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. High performance copper aluminium condenser class T, ambient temperature + 43°. Output per cycle (+65°/+10°) kg. 80. Output per cycle (+65°/-18°) kg. 55. Heating element in the door frame. Hot gas defrosting system. R452A ecological refrigerant fluid. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x450x1130 mm. Minimum wheelbase for tray holder guides 18,25 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 60 mm. |
|
MC161R MULTIF BLAST CHILLER 16 GN 171 AIR P | Elettrica | 790 x 870 x 1960 | Download |
Detail
MC161R MULTIF BLAST CHILLER 16 GN 171 AIR P Multifunction blast chiller with remote air cooling system, tray capacity GN 1/1 x 28/18/14, distance between trays 37/55/73 mm. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. Output per cycle (+65°/+10°) kg. 65. Output per cycle (+65°/-18°) kg. 55. Heating element in the door frame. Hot gas defrosting system. Copper-aluminium evaporator with cataphoresis anti-corrosion treatment. High performance copper-aluminium condenser. Inner dimensions of the chamber 670x450x1130 mm. Minimum wheelbase for tray holder guides 18,25 mm. High density polyuretane's insulation (approx 42 kg/m3). HCFC free. Side Panel thickness: 60 mm. Back panel thickness 60 mm. Remote condensing unit not included. |
|
MCP201 MULTIF BLAST CHILLER 20 GN 1/1 AIR P | Elettrica | 1300 x 1275 x 2300 | Download |
Detail
MCP201 MULTIF BLAST CHILLER 20 GN 1/1 AIR P Multifunction blast chiller suitable for tray holder rack 20 x GN 1/1 with remote air cooling system. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. High performance copper aluminium condenser class T, ambient temperature + 43°. Output per cycle (+65°/+10°) kg. 140. Output per cycle (+65°/-18°) kg. 80. Heating element in the door frame. Hot gas defrosting system. Inner dimensions of the chamber 680x950x1820 mm. Side Panel thickness: 80 mm. Back panel thickness 60 mm. Remote condensing unit. |
|
MCP202 MULTIF BLAST CHILL 40GN1/1-20GN2/1 AIR P | Elettrica | 1500 x 1475 x 2300 | Download |
Detail
MCP202 MULTIF BLAST CHILL 40GN1/1-20GN2/1 AIR P Multifunction blast chiller suitable for tray holder rack 20 GN 2/1 - 40 GN 1/1 with remote air cooling system. 7'' touch-screen control panel with 5 options: positive blast chilling + conservation phase, negative blast chilling + conservation phase, thawing, proofing retarder, low temperature cooking + chilling, low temperature cooking. working temperature range +85° / -18°. High performance copper aluminium condenser class T, ambient temperature + 43°. Output per cycle (+65°/+10°) kg. 170. Output per cycle (+65°/-18°) kg. 110. Heating element in the door frame. Hot gas defrosting system. Inner dimensions of the chamber 680x950x1820 mm. Side Panel thickness: 80 mm. Back panel thickness 60 mm. Remote condensing unit. |